The FMC-10 has been designed to operate in the full range of environments from commercial premises through to heavy industrial applications which may require hazardous area sensing.
A fixed single point alarm unit that meets the requirements for economic and reliable monitoring of gas levels in a wide range of environments from commercial premises through to heavy industrial applications which may require hazardous area sensing. Typical monitor locations are - public buildings, boiler plant rooms, swimming pools, water treatment works, H&V control systems, manufacturing and process plants.
Key Features:
- Flammable, Oxygen or Toxic Gases
- Wall or panel mount
- Two alarm stages + relays
- Internal or remote sensor
- Compact size
- Low power consumption
- 4-20mA analogue output
- Sealed to IP65 rating
- Extensive fault detection circuitry
- Delay to alarm options
Applications:
- Petrochemical industry
- Chemical industry
- Storage facilities
- Process plants
- LNP facilities
- Waste water treatment
Specifications:
Measuring Range:
- Combustible Gas - LEL, % Vol, ppm
- Toxic Gas - ppm, % Vol
- Oxygen - % vol - Depletion or Enrichment
- Any 4~20mA input signal
Indicators:
- Digital Display 31/2 Digit
- Power - Green L.E.D.
- Switch on delay power indicator flashing - 45 seconds
- Alarms Lo/Hi - Red L.E.Ds
- Fault - Amber L.E.D.
- System Test - Alarm L.E.D.s flashing
- Alarm relay inhibit - Fault L.E.D. on
Audible Alarm:
- Low, High and Fault Alarms
Power Supply:
- 230/115v AC 50/60 Hz or 24vDC
- The two voltages may be utilized simultaneously - stand
Power Consumption:
- 4 watts - full alarm
Outputs:
- Low, High and fault alarm relays -SPCO normally de-energized - energized option
- Lo gas alarm relay SPCO normally energized - de-energized option
- latched or unlatched
- Fault relay SPCO normally de-energized - energized option
- All contacts rated 5A - 230v AC
- 4-20mA/1-5v
- Output 24vDC @ 100mA max - auxiliary equipment (non inductive)
Alarm Settings:
- Digital setting (fully adjustable between zero and full scale)
- Delay to alarm options - 10/30 seconds, 10 minutes
Sensor Inputs:
- Bridge type 3 wire detector mv (Catalytic)
- 4-20mA (electrochemical / infrared)
Sensor Cable:
- 3 core 1.5mm2 screened 1.5km
Miscellaneous:
- Operating temperature -10 to +50°C
- Storage temperature -10 to 65°C
- Alarm relay inhibit during calibration
- Sounder Inhibit
- System function test switch
- Dimensions L 200mm H 120mm D 58mm
- Weight 0.8 kg
- Protection IP65
- Field Terminals - screw type 2.5mm
- Cable entry - top, bottom, sides, rear
*Specifications are subject to change